{"title":"Light Sources","description":"\u003csection\u003e\n  \u003ch2\u003eEndoscopy Light Sources and Accessories\u003c\/h2\u003e\n  \u003cp\u003eExplore light sources for surgical endoscopy, including LED and xenon systems used with compatible scopes and light guides. Chicago Medical Sales brings together equipment for hospitals, surgical teams, biomedical technicians and medical equipment resellers.\u003c\/p\u003e\n\n  \u003ch3\u003eLED Light Sources\u003c\/h3\u003e\n  \u003cp\u003eLED models in this collection include Stryker L9000 and L10 AIM units. When comparing systems, check the exact model, supported imaging platform, light cable connection and accessories included with the individual unit.\u003c\/p\u003e\n\n  \u003ch3\u003eXenon Light Sources\u003c\/h3\u003e\n  \u003cp\u003eBrowse xenon systems such as the Stryker X6000, X7000 and X8000, CONMED Linvatec LS7700 and DYONICS 300XL. For a pre-owned unit, review the stated lamp condition or operating hours alongside the model number and listing details.\u003c\/p\u003e\n\n  \u003ch3\u003eLamps and Fiberoptic Light Cables\u003c\/h3\u003e\n  \u003cp\u003eReplacement xenon lamps and fiberoptic light cables are listed alongside the consoles they support. Match a lamp by part number and a cable by its fittings, diameter and length; compatibility should be confirmed for both the light source and the scope.\u003c\/p\u003e\n\n  \u003cp\u003eEach listing specifies the equipment or component offered. Check its condition, included accessories and compatibility before ordering.\u003c\/p\u003e\n\u003c\/section\u003e","products":[{"product_id":"stryker-x7000-endoscope-light-source-pn-220-190-000-new-xenon-light-bulb","title":"STRYKER X7000 ENDOSCOPE LIGHT SOURCE, PN 220-190-000 - NEW XENON LIGHT BULB","description":"\u003cp\u003eThe Stryker X7000 Endoscope Light Source (P\/N 220-190-000) provides illumination for endoscopic procedures using a 300 W elliptical xenon bulb. It is designed for use with Stryker endoscopy camera systems, including the 1088 platform.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulb:\u003c\/strong\u003e New bulb included, as stated by the seller; rated life is approximately 500 hours when used properly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Tested at the seller’s facility for several hours; functions verified by a qualified biomedical technician\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeatures:\u003c\/strong\u003e Adjustable light output, internal safety checks, thermal protection, warning\/error codes, Ethernet interface and SIDNE compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e With a compatible ESST light cable, the unit can enter Standby when the scope is disconnected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe seller reports compatibility with Stryker 1088, 1188 and 1288 systems. Confirm compatibility with your system and cable configuration before purchase.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905943421089,"sku":"X7000","price":895.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-x7000-endoscope-light-source-pn-220-190-000-new-xe.jpg?v=1790533297"},{"product_id":"stryker-x8000-endoscope-light-source-220-200-000-new-xenon-light-bulb","title":"STRYKER X8000 ENDOSCOPE LIGHT SOURCE, 220-200-000 - NEW XENON LIGHT BULB","description":"\u003cp\u003eThe Stryker X8000 Xenon Endoscope Light Source (P\/N 220-200-000) provides illumination for endoscopic procedures through a fiberoptic light cable. It uses a 300 W elliptical xenon bulb and includes a bulb described by the seller as new and low-hours.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Tested at the seller’s facility for several days; functions verified by a qualified biomedical technician\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulb life:\u003c\/strong\u003e Approximately 500 hours when used properly, according to the manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Shows brightness, bulb hours and warning\/error codes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e With a compatible ESST cable, the unit can enter Standby when the scope is disconnected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe seller reports compatibility with Stryker 1088, 1188 and 1288 camera systems and the L9000 model. Please confirm compatibility with your system and cable configuration before purchase.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905943453857,"sku":"X8000","price":1095.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-x8000-endoscope-light-source-220-200-000-new-xenon.jpg?v=1790533297"},{"product_id":"stryker-x6000-endoscope-light-source-220-185-000-new-300w-xenon-light-bulb","title":"STRYKER X6000 ENDOSCOPE LIGHT SOURCE, 220-185-000 - NEW 300W XENON LIGHT BULB","description":"\u003cp\u003eThe Stryker X6000 Xenon Endoscope Light Source (P\/N 220-185-000) provides illumination for endoscopic procedures and is designed for use with Stryker medical video cameras. It uses a 300 W Xenon Cermax lamp. A new xenon bulb is included, as stated by the seller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Good working condition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Tested at the seller’s facility; functions verified by a qualified biomedical technician\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Electronic Scope Sensing Technology (ESST) can place the unit in standby when a compatible ESST cable detects that the scope has been disconnected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamp life:\u003c\/strong\u003e Approximately 500 hours with proper use, according to the manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatibility with Stryker 888, 988, 1088, 1188 and 1288 camera systems. Confirm system and cable compatibility before purchase.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905943486625,"sku":"X6000","price":695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-x6000-endoscope-light-source-220-185-000-new-300w.jpg?v=1790533297"},{"product_id":"stryker-endoscope-light-cable-233-050-064","title":"STRYKER ENDOSCOPE LIGHT CABLE, 233-050-064","description":"\u003cp\u003eStryker fiberoptic light cable, P\/N 233-050-064, with a 5.0 mm diameter and 10 ft length. The clear case allows visual inspection of the fiber bundle. It has screw-on fittings for a Storz scope and a Stryker light source, and is listed for use with Stryker X7000, X8000 and L9000 light sources.\u003c\/p\u003e\n\n\u003cp\u003eMatch the cable diameter and fittings to the endoscope and light source before use.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905943519393,"sku":"233-050-064","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-endoscope-light-cable-233-050-064.jpg?v=1790533297"},{"product_id":"stryker-endoscope-light-cable-233-050-100","title":"STRYKER ENDOSCOPE LIGHT CABLE, 233-050-100","description":"\u003cp\u003eThe Stryker 233-050-100 is a 5.0 mm × 10 ft clear-case Safelight fiberoptic cable for transmitting light from a compatible Stryker light source to an endoscope. It is specified for use with Stryker X7000 and X8000 light source models.\u003c\/p\u003e\n\u003cp\u003eA compatible Safelight scope adapter may be required for the endoscope connection; confirm whether an adapter is included with the item.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905943552161,"sku":"233-050-100","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-endoscope-light-cable-233-050-100.jpg?v=1790533297"},{"product_id":"stryker-endoscope-light-cable-233-050-065","title":"STRYKER ENDOSCOPE LIGHT CABLE, 233-050-065","description":"\u003cp\u003eStryker fiberoptic light cable, P\/N 233-050-065, measuring 5.0 mm in diameter and 10 ft in length. It has fittings for Stryker scopes and Stryker light sources and is designed to transmit illumination from a compatible light source to an endoscope.\u003c\/p\u003e\n\n\u003cp\u003eListed for use with Stryker X7000, X8000 and L9000 light sources. Match the cable diameter and fittings to the endoscope and light source before use.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905943879841,"sku":"233-050-065","price":175.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-endoscope-light-cable-233-050-065.jpg?v=1790533313"},{"product_id":"stryker-endoscope-light-cable-233-050-010","title":"STRYKER ENDOSCOPE LIGHT CABLE, 233-050-010","description":"\u003cp\u003eStryker fiberoptic endoscope light cable, listed as P\/N 233-050-010. The supplied specifications describe a 6.5 mm diameter, 10 ft cable with Wolf scope and Stryker light source fittings. It connects a compatible light source to an endoscope to transmit illumination during endoscopic procedures.\u003c\/p\u003e\n\n\u003cp\u003eListed for use with Stryker X7000, X8000 and L9000 light sources. Confirm that the cable fittings match the specific light source and endoscope before purchase.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905943912609,"sku":"233-050-010","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-endoscope-light-cable-233-050-010.jpg?v=1790533313"},{"product_id":"stryker-endoscope-light-cable-233-050-069","title":"STRYKER ENDOSCOPE LIGHT CABLE, 233-050-069","description":"\u003cp\u003eUsed Stryker fiberoptic light cable, P\/N 233-050-069. The 5 mm × 10 ft clear-case cable transmits light from a compatible Stryker light source to an endoscope. It has snap-on fittings for Wolf scopes and Stryker light sources and is listed for use with Stryker X7000 and X8000 light source models.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905943945377,"sku":"233-050-069","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-endoscope-light-cable-233-050-069.jpg?v=1790533313"},{"product_id":"stryker-l9000-endoscope-light-source-220-210-000","title":"STRYKER L9000 ENDOSCOPE LIGHT SOURCE, 220-210-000","description":"\u003cp\u003eSTRYKER L9000(220-210-000) ENDOSCOPE LIGHT SOURCE.\u003c\/p\u003e\n\n\u003cp\u003eTHE LIGHT SOURCE WAS TESTED FOR FEW DAYS IN OUR FACILITY, ALL THE FUNCTIONS WERE VERIFIED BY A BIOTECH QUALIFIED TECHNICIAN.\u003c\/p\u003e\n\n\u003cp\u003eTHIS MODEL IS FULLY COMPATIBLE WITH THE 1288 \/ 1488 SYSTEMS.\u003c\/p\u003e\n\n\u003cdiv\u003e\n\u003cp\u003eNow an eco-friendly and cost savings OR device, the L9000 LED Light Source reduces hazardous environmental waste by preventing frequent changes of light bulbs.\u003c\/p\u003e\n\n\u003cp\u003eAs an added benefit, the optional Safelight technology ensures that the light source goes into standby mode when the Safelight cable detaches from the scope. This feature will reduce the risk of injury to the patient and OR staff.\u003c\/p\u003e\n\n\u003cp\u003eThis LED light source is a great solution when used with the 1288 HD 3-Chip Camera as the light output settings are completely controllable from the camera head. Overall lower operating cost and increased safety make this device a sure winner in the OR\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 class=\"subTitle\"\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e \u0026amp; Benefits\u003c\/h3\u003e\n\n\u003cul class=\"list\"\u003e\n\t\u003cli class=\"listLink\"\u003eSafelight technology for increased patient and OR safety\u003c\/li\u003e\n\t\u003cli class=\"listLink\"\u003eRemotely controllable from 1288 HD 3-Chip Camera Head\u003c\/li\u003e\n\t\u003cli class=\"listLink\"\u003eCost savings\u003c\/li\u003e\n\t\u003cli class=\"listLink\"\u003eEco-friendly\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905944076449,"sku":"L9000","price":1145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-l9000-endoscope-light-source-220-210-000.jpg?v=1790533313"},{"product_id":"stryker-endoscope-light-cable-233-050-084","title":"STRYKER ENDOSCOPE LIGHT CABLE, 233-050-084","description":"\u003cp\u003eThe Stryker fiber-optic endoscope light cable, P\/N 233-050-084, measures 5.0 mm in diameter and 10 ft in length. It has a screw-on fitting for a Storz scope and a Stryker light-source fitting, and is suitable for use with compatible Stryker X7000 and X8000 light sources.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Stryker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e 233-050-084\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable type:\u003c\/strong\u003e Fiber-optic light cable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiameter:\u003c\/strong\u003e 5.0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 10 ft\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFittings:\u003c\/strong\u003e Storz scope and Stryker light source, screw-on\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible light sources:\u003c\/strong\u003e Stryker X7000 and X8000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905944928417,"sku":"233-050-084","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-endoscope-light-cable-233-050-084.jpg?v=1790533347"},{"product_id":"stryker-x7000-endoscope-light-source-pn-220-190-000-50-hours-xenon-light-bulb","title":"STRYKER X7000 ENDOSCOPE LIGHT SOURCE, PN 220-190-000 - 70 HOURS XENON LIGHT BULB","description":"\u003cp\u003eThe Stryker X7000 Xenon Endoscope Light Source, P\/N 220-190-000, provides illumination through a fiber-optic light cable for endoscopic applications. It uses a 300 W Xenon lamp. The bulb-hour meter is reported to show approximately 70 hours; the X7000 manual recommends replacing the lamp at 500 hours or if illumination becomes insufficient.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Stryker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e X7000 Xenon Light Source\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e 220-190-000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLamp:\u003c\/strong\u003e 300 W Xenon\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBulb-hour reading:\u003c\/strong\u003e Approximately 70 hours, as reported by the seller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Tested for several hours at the seller’s facility; functions verified by a qualified biomedical technician\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe seller reports compatibility with Stryker 1088, 1188, and 1288 systems. The unit uses Stryker light cables and may be connected to compatible rigid or flexible endoscopes with the appropriate cable and adapters. Confirm system and lamp-module compatibility before purchase; this listing does not claim that X7000 and X8000 lamp modules are interchangeable.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905945190561,"sku":"X7000","price":625.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-x7000-endoscope-light-source-pn-220-190-000-70-hou.jpg?v=1790533347"},{"product_id":"stryker-x6000-endoscope-new-light-bulb-pn-220-185-300","title":"STRYKER X6000 ENDOSCOPE NEW LIGHT BULB, PN 220-185-300","description":"\u003cp\u003eThe Stryker X6000 replacement Xenon lamp module, P\/N 220-185-300, is specified for use with the X6000 endoscope light source. The lamp is rated at 300 W. The X6000 manual identifies this part number for lamp replacement.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Stryker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible model:\u003c\/strong\u003e X6000 endoscope light source\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e 220-185-300\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLamp type:\u003c\/strong\u003e 300 W Xenon\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Tested at the seller’s facility; functions verified by a qualified biomedical technician\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 30 days\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eReplacement lamp module only; the X6000 light source is not included. Install according to the manufacturer’s instructions.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905946075297,"sku":"X6000","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-x6000-endoscope-new-light-bulb-pn-220-185-300.jpg?v=1790533363"},{"product_id":"stryker-x7000-endoscope-new-light-bulb-pn-220-191-000-30-day-warranty","title":"STRYKER X7000 ENDOSCOPE NEW LIGHT BULB, PN 220-191-000, 30-Day Warranty","description":"\u003cp\u003eThe Stryker X7000 replacement Xenon lamp module, P\/N 220-191-000, is designed for use with the X7000 endoscope light source. The module contains a 300 W Xenon lamp. Stryker’s manual identifies this part number as the replacement lamp module for the X7000.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Stryker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible model:\u003c\/strong\u003e X7000 endoscope light source\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e 220-191-000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLamp type:\u003c\/strong\u003e 300 W Xenon\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Tested at the seller’s facility; functions verified by a qualified biomedical technician\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 30 days\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eReplacement lamp module only; the X7000 light source is not included. Install and check the lamp according to the manufacturer’s instructions.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905946108065,"sku":"X7000","price":695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-x7000-endoscope-new-light-bulb-pn-220-191-000-30-d.jpg?v=1790533379"},{"product_id":"stryker-x8000-endoscope-new-light-bulb-pn-220-201-000","title":"STRYKER X8000 ENDOSCOPE NEW LIGHT BULB, PN 220-201-000","description":"\u003cp\u003eThe Stryker X8000 replacement Xenon bulb module, P\/N 220-201-000, is designed for use with the Stryker X8000 endoscope light source. The X8000 uses a 300 W Xenon lamp to provide illumination through a fiber-optic light cable. This is the replacement bulb module only; the light source and other accessories are not included.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Stryker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible model:\u003c\/strong\u003e X8000 endoscope light source\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e 220-201-000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLamp type:\u003c\/strong\u003e 300 W Xenon bulb module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Tested at the seller’s facility; functions verified by a qualified biomedical technician\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 30 days\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eInstall and verify the bulb module according to the X8000 manufacturer instructions. The manufacturer’s manual specifies this part number for the X8000 replacement bulb module.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905946140833,"sku":"X8000","price":875.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-x8000-endoscope-new-light-bulb-pn-220-201-000.jpg?v=1790533379"},{"product_id":"dyonics-300xl-light-source-7206084-300w-xenon-light-bulb","title":"DYONICS 300XL LIGHT SOURCE, 7206084 - 300W XENON LIGHT BULB","description":"\u003cp\u003eSmith \u0026amp; Nephew DYONICS 300XL Xenon Light Source, REF 7206084. This 300 W endoscope light source provides 5700–6000 K illumination and is designed for endoscopic procedures. It accepts light guide fittings for Dyonics\/Wolf, Olympus, ACMI, and Storz systems. Tested in our facility for several hours, with all functions verified by a qualified biomedical technician.\u003c\/p\u003e","brand":"Smith \u0026 Nephew - Dyonics","offers":[{"title":"Default Title","offer_id":47905946173601,"sku":"300XL-7206084","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/dyonics-300xl-light-source-7206084-300w-xenon-light-bulb.jpg?v=1790533379"},{"product_id":"stryker-x8000-endoscope-light-source-220-200-000-under-100hours-xenon-light-bulb","title":"STRYKER X8000 ENDOSCOPE LIGHT SOURCE, 220-200-000 - UNDER 100HOURS XENON LIGHT BULB","description":"\u003cp\u003eThe Stryker X8000 (P\/N 220-200-000) is a xenon light source for endoscopic procedures. It uses a 300 W elliptical xenon lamp and delivers illumination through a compatible fiberoptic light cable. The recently replaced lamp has less than 100 hours of use, according to the displayed hour reading; the lamp is rated for approximately 500 hours.\u003c\/p\u003e\n\n\u003cp\u003eThe X8000 includes an LCD display for bulb-hour readings and warning or error codes, and a safety shutoff that activates if the bulb assembly overheats. When used with an ESST light cable, it can enter standby if the scope disconnects from the cable. The light source was tested at our facility for several days, and all functions were verified by a qualified biomedical technician.\u003c\/p\u003e\n\n\u003cp\u003eSuitable for endoscopy setups using compatible Stryker 1088, 1188, or 1288 camera systems.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905946435745,"sku":"X8000","price":745.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-x8000-endoscope-light-source-220-200-000-under-100.jpg?v=1790533379"},{"product_id":"conmed-linvatec-ls7700-light-source","title":"ConMed Linvatec LS7700 Light Source","description":"\u003cp\u003eThe ConMed Linvatec LS7700 is a 300 W xenon light source for endoscopic applications. It delivers light through a compatible fiberoptic guide and uses an optical system designed to improve numerical aperture and distribute light. The universal light-guide receptacle accommodates compatible guide fittings and adapters.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures and specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eLamp: 300 W xenon short-arc\u003c\/li\u003e\n  \u003cli\u003eLamp life: 500 hours, with an on-screen hours-remaining indicator\u003c\/li\u003e\n  \u003cli\u003eStandby button for placing the light source in standby mode\u003c\/li\u003e\n  \u003cli\u003eManual or automatic intensity control\u003c\/li\u003e\n  \u003cli\u003eUniversal light-guide receptacle for compatible fittings and adapters\u003c\/li\u003e\n  \u003cli\u003eTypical light output: 1,300–1,800 lumens\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ConMed Linvatec","offers":[{"title":"Default Title","offer_id":47905946992801,"sku":"LS7700","price":1375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/conmed-linvatec-ls7700-light-source.jpg?v=1790533397"},{"product_id":"stryker-x7000-endoscope-light-source-pn-220-190-000-30-hours-xenon-light-bulb","title":"STRYKER X7000 ENDOSCOPE LIGHT SOURCE, PN 220-190-000 - 30 HOURS XENON LIGHT BULB","description":"\u003cp\u003eThe Stryker X7000 Xenon Endoscope Light Source (P\/N 220-190-000) provides illumination for endoscopic procedures through a compatible fiberoptic light cable. It uses a 300 W elliptical xenon lamp with approximately 30 hours of use; the lamp is rated for approximately 500 hours. The X7000 is compatible with Stryker light cables and can be used in endoscopy setups with Stryker 1088, 1188, and 1288 camera systems.\u003c\/p\u003e\n\n\u003cp\u003eThe light source was tested at our facility for several hours, and all functions were verified by a qualified biomedical technician.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905947222177,"sku":"X7000","price":675.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-x7000-endoscope-light-source-pn-220-190-000-30-hou.jpg?v=1790533397"},{"product_id":"stryker-l10-endoscope-light-source-220-220-300","title":"STRYKER L10 LED AIM Light Source, PN 220-220-300","description":"\u003cp\u003eThe Stryker L10 LED Light Source with AIM (P\/N 220-220-300) provides endoscopic illumination with visible LED white light and supports AIM modes for near-infrared fluorescence imaging (ENV) and ureteral transillumination (IRIS), when used with the required compatible system components.\u003c\/p\u003e\n\n\u003cp\u003eThis unit was tested at our facility for several days, and its functions were verified by a qualified biomedical technician. It is compatible with the Stryker 1588 AIM camera system.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTechnical specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eElectrical input: 100–240 VAC, 50\/60 Hz, 3.2–1.3 A\u003c\/li\u003e\n  \u003cli\u003eDimensions: 12.1 × 31.8 × 42.7 cm\u003c\/li\u003e\n  \u003cli\u003eWeight: 7.3 kg\u003c\/li\u003e\n  \u003cli\u003eLight engine: red, green and blue LEDs; 808 nm and 830 nm lasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatibility and accessories:\u003c\/strong\u003e ENV mode requires a Stryker 1588 AIM Camera Control Unit and AIM SafeLight cable (P\/N 0233-050-300). IRIS mode requires the IRIS Ureteral Kit (P\/N 0220-180-518). A safety feature reduces light output when the fiber-optic cable is not properly connected to the scope adapter.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSales notice:\u003c\/strong\u003e For sale or export outside the United States. Buyers with a U.S. shipping address should contact the seller before purchase.\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":47905947484321,"sku":"L10","price":3050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/files\/stryker-l10-led-aim-light-source-pn-220-220-300.jpg?v=1790533413"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/6619\/4593\/collections\/ChatGPT_Image_Sep_25_2026_05_24_33_AM.png?v=1790303098","url":"https:\/\/chicagomedicalsales.com\/collections\/light-sources.oembed","provider":"Chicago Medical Sales","version":"1.0","type":"link"}